Tel : +86 13376987741
E-mail : niko@fenoux.com
Item NO.:
9907-022Payment:
T/T 、PayPal、Western UnionProduct Origin:
United StatesShipping Port:
XiamenLead Time:
1-2daysProduct Detail
9907-022 Woodward SPEED CONTROL MODULE
Brand:WoodWard | Model number:9907-022 |
Colour:new | Warranty: 12 months |
Lead Time:3-day working day | Country of origin: United States |
Price: Please contact us | Product weight:1.2kg |
Packaging & Delivery
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Product Details
9907-022
SPEED CONTROL MODULE
LOW VOLTAGE
2301A FORWARD ACTING SPEED CONTROL
Woodward makes models of its Load Sharing Module
for use with engines equipped with speed controls that
accept a ±3 Vdc speed setting input, a 0.5 to 4.5 Vdc
input, or a PWM (pulse-width-modulated) input. The
Load Sharing Module allows use of Woodward power
generation accessories and allows load sharing
between engines equipped with speed controls
that are not manufactured by Woodward and
engines controlled with Woodward electronic
controls, or controls using other Woodward load
sharing modules.
Power Supply
DC Models 18–32 Vdc, approximately 5 W.
AC Models Jumper selectable for 95–130 or 190–260 Vac line-to-line,
50–400 Hz, approximately 10 W.
Inputs
3-phase PT Inputs 95–130 or 190–260 Vac line-to-line, 50–400 Hz.
PT input burden is 1.6 W per phase at 240 Vac, 0.4 W per phase at 120 Vac.
3-phase CT Inputs 3–7 Arms at full load, CT input burden at full load is 0.1 VA per phase.
Load Sharing Input 0–3 Vdc into 25 k impedance in isochronous mode, open circuit in droop mode.
Sync Input Compatible with optional Woodward SPM-A synchronizer.
Speed Trim Allows manual adjustment of output level with an external 10 k potentiometer (not available
on part number 9907-173).
Droop Switch The external droop switch is to be wired in series with the auxiliary circuit breaker contact.
Droop mode is selected when either the droop switch or the auxiliary circuit breaker is open.
Outputs
Load Signal DC signal proportional to total real current sensed by the Load Sharing Module.
Used to adjust load gain.
Output to Speed Control +0.5 to +4.5 Vdc analog, ±3 Vdc analog, or PWM, depending on model.
Adjustments
Droop Provides for output reduction between no-load and full-load conditions.
Load Gain Provides adjustment of the load on an individual generator when two or more generators are
paralleled. Adjusts specified full load condition from 3 to 7 Arms.
Environmental
Operating Temperature –40 to +70 °C (–40 to +158 °F).
Salt Fog Tested at 5% NaCl, 35 °C, 47 hrs wet, 47 hrs dry.
Humidity Tested at 95% RH, 65 °C, non-condensing, 5 cycles at 24 hrs/cycle.
Vibration Swept sine: Tested at 4 G, 5 mm, 5–2000 Hz, 3 hr min/axis, including 4 30-minute dwells at
resonant frequencies.
Shock 40 G, 11 ms sawtooth pulse.
Installation Overvoltage
Category Category III.
Air Quality Pollution Degree 2.
Mounting Any orientation, any convenient location, but not on engine. IP43 protective enclosure
required for compliance with EU Low Voltage Directive.
Physical Characteristics
Dimensions Length: 273.6 mm (10.77 in.)
Width: 214.1 mm (8.43 in.)
Height: 59.2 mm (2.33 in.)
Weight/Mass 1398 g (49.3 oz.) approximate, dc models
1488 g (52.5 oz.) approximate, dc models
Safety and EMC Standards Compliance
Conforms to EMC Directive 89/336/EEC. Conformity established by testing to EN 50081-2, EN 50082-2.
Conforms to Low Voltage Directive 73/23/EEC when used in accordance with instructions. Conformity established by
testing to EN 50178, 1997, and EN 61010-1, 1993, +A1.
Listed to UL and cUL Industrial Control Equipment (UL508).
RELATED PRODUCTS
5501-381 | WOODWARD | 5466-1047 | WOODWARD |
8200-226 | WOODWARD | 5466-1049 | WOODWARD |
8250-565 | WOODWARD | 5466-253 | WOODWARD |
8272-582 | WOODWARD | 5501-365 | WOODWARD |
8290-189 | WOODWARD | 723PLUS | WOODWARD |
8290-191 | WOODWARD | 8200-203 | WOODWARD |
8290-195 | WOODWARD | 8235-622 | WOODWARD |
8405-307 | WOODWARD | 8251-766 | WOODWARD |
8406-113 | WOODWARD | 8405-011 | WOODWARD |
8407-522 | WOODWARD | 8405-084 | WOODWARD |
8440-1706 | WOODWARD | 9904-041 | WOODWARD |
8440-1831 | WOODWARD | 9905-028 | WOODWARD |
PCU-DPIO V4.6.3 | WOODWARD | 9905-392 | WOODWARD |
1680-2004 | WOODWARD | 9905-463 | WOODWARD |
8235-154 | WOODWARD | 9905-792 | WOODWARD |
8250-573 | WOODWARD | 9905-990 | WOODWARD |
8273-140 | WOODWARD | 9907-1106 | WOODWARD |
8440-2165 | WOODWARD | 9907-186 | WOODWARD |
8901-457 | WOODWARD | 9907-205 | WOODWARD |
8923-1633 | WOODWARD | 9907-345 | WOODWARD |
Contact person:Niko
Email Address::niko@fenoux.com
WhatApp: +86 13376987741
Related Tags :